Compare TONGHUI TH2822A, TH2822C, TH2822D and TH2822E handheld LCR meters by test frequency, basic accuracy and DCR capability.
Model Selection
| Model |
Maximum AC test frequency |
Basic accuracy* |
DCR |
AC test levels |
| TH2822A |
10kHz |
0.25% |
Not supported |
0.6Vrms |
| TH2822C |
100kHz |
0.25% |
Not supported |
0.6Vrms |
| TH2822D |
10kHz |
0.1% |
Supported |
0.3 / 0.6 / 1Vrms |
| TH2822E |
100kHz |
0.1% |
Supported |
0.3 / 0.6 / 1Vrms |
*Basic accuracy applies under the specified conditions; refer to the model-specific manual for frequency, impedance, level and range dependencies.
Specifications and included items depend on the selected model. Review the model-specific details below before ordering.
TONGHUI TH2822A — Model Details
The TONGHUI TH2822A handheld LCR meter measures inductance, capacitance, resistance and impedance at four selectable test frequencies: 100Hz, 120Hz, 1kHz and 10kHz. Its portable format suits routine component checks at the workbench or during electronics repair.
A 40,000-count primary display and a separate secondary readout let you view a component value alongside a related parameter. The 0.6Vrms test signal, automatic ranging and series or parallel equivalent circuits support a consistent measurement setup, while Mini-USB communication connects the meter to a PC for remote operation and data collection.
Key Features
-
Selectable test frequencies: Four fixed AC settings through 10kHz let you compare component readings at a defined test frequency.
-
Dual-parameter display: Read the primary component value with a related secondary parameter on the dual LCD. The primary display provides up to 40,000 counts; basic accuracy is 0.25% under the conditions specified in the operation manual.
-
Component and loss-related measurements: Measure L, C, R and impedance, with dissipation factor, quality factor, phase angle and ESR available as secondary parameters.
-
Automatic setup support: Automatic ranging and auto LCR selection help establish the primary parameter and equivalent circuit when checking mixed or unknown components.
-
Tolerance sorting: Use 1%, 5%, 10% or 20% tolerance settings to sort components against a stored nominal value.
-
Mini-USB PC communication: A virtual serial interface supports remote control and transfer of measurement results, so readings can be collected as part of a PC-based workflow.
Applications
- Checking resistors, capacitors and inductors during electronics repair and maintenance.
- Evaluating passive-component values and loss-related parameters at the workbench.
- Sorting components against a nominal value with the tolerance function.
Why Choose the TH2822A?
Choose the TH2822A for routine L/C/R/Z measurements at selectable frequencies through 10kHz, with tolerance sorting and PC communication in a handheld instrument. It suits work that needs component values and loss-related measurements without moving every check to a bench LCR meter.
Basic accuracy depends on the measurement frequency, range, test level and operating conditions. See the operation manual for the applicable accuracy tables.
Source
TONGHUI TH2822C — Model Details
The TONGHUI TH2822C handheld LCR meter measures inductance, capacitance, resistance and impedance at five selectable test frequencies: 100Hz, 120Hz, 1kHz, 10kHz and 100kHz. It supports component checks that require measurements at several defined AC frequencies.
The dual display combines a 40,000-count primary reading with a secondary parameter such as dissipation factor, quality factor, phase angle or ESR. Automatic ranging, auto LCR selection and a 0.6Vrms test signal support routine measurement work; Mini-USB communication allows PC control and collection of readings.
Key Features
-
Selectable test frequencies: Five fixed AC settings through 100kHz let you compare component readings at a defined test frequency.
-
Dual-parameter display: Read the primary component value with a related secondary parameter on the dual LCD. The primary display provides up to 40,000 counts; basic accuracy is 0.25% under the conditions specified in the operation manual.
-
Component and loss-related measurements: Measure L, C, R and impedance, with dissipation factor, quality factor, phase angle and ESR available as secondary parameters.
-
Automatic setup support: Automatic ranging and auto LCR selection help establish the primary parameter and equivalent circuit when checking mixed or unknown components.
-
Tolerance sorting: Use 1%, 5%, 10% or 20% tolerance settings to sort components against a stored nominal value.
-
Mini-USB PC communication: A virtual serial interface supports remote control and transfer of measurement results, so readings can be collected as part of a PC-based workflow.
Applications
- Checking resistors, capacitors and inductors during electronics repair and maintenance.
- Evaluating passive-component values and loss-related parameters at the workbench.
- Sorting components against a nominal value with the tolerance function.
Why Choose the TH2822C?
Choose the TH2822C when 100kHz is a required test point in a portable LCR workflow. Its five frequency settings, secondary-parameter display and tolerance mode support component evaluation and sorting, while the USB interface allows readings to be collected on a PC.
Basic accuracy depends on the measurement frequency, range, test level and operating conditions. See the operation manual for the applicable accuracy tables.
Source
TONGHUI TH2822D — Model Details
The TONGHUI TH2822D handheld LCR meter combines AC inductance, capacitance, resistance and impedance measurements with a dedicated DC resistance function. Its four selectable AC test frequencies are 100Hz, 120Hz, 1kHz and 10kHz.
Selectable 0.3Vrms, 0.6Vrms and 1Vrms AC test levels let you set the measurement signal for the component being checked. The 40,000-count primary display, secondary-parameter readout and Mini-USB communication support both local component evaluation and PC-based collection of results.
Key Features
-
Selectable test frequencies: Four fixed AC settings through 10kHz let you compare component readings at a defined test frequency.
-
Dual-parameter display: Read the primary component value with a related secondary parameter on the dual LCD. The primary display provides up to 40,000 counts; basic accuracy is 0.1% under the conditions specified in the operation manual.
-
LCR, impedance and DCR measurements: Check L, C, R and impedance with AC excitation, then use DCR for direct DC resistance measurement. D, Q, phase angle and ESR provide additional component information.
-
Three selectable AC levels: Choose 0.3Vrms, 0.6Vrms or 1Vrms to define the AC test signal for the measurement task.
-
Tolerance sorting: Use 1%, 5%, 10% or 20% tolerance settings to sort components against a stored nominal value. Auto LCR selection assists with mixed component checks.
-
Mini-USB PC communication: A virtual serial interface supports remote control and transfer of measurement results, so readings can be collected as part of a PC-based workflow.
Applications
- Checking resistors, capacitors and inductors during electronics repair and maintenance.
- Evaluating AC component parameters and DC resistance at the workbench.
- Sorting components against a nominal value with the tolerance function.
Why Choose the TH2822D?
Choose the TH2822D when a handheld workflow calls for both AC component parameters through 10kHz and direct DC resistance readings. Its selectable test levels, auto LCR function and tolerance sorting support a repeatable setup for component checks and repair work.
Basic accuracy depends on the measurement frequency, range, test level and operating conditions. See the operation manual for the applicable accuracy tables.
Source
TONGHUI TH2822E — Model Details
The TONGHUI TH2822E handheld LCR meter measures AC inductance, capacitance, resistance and impedance at five selectable frequencies: 100Hz, 120Hz, 1kHz, 10kHz and 100kHz. A dedicated DCR function adds direct DC resistance measurement to the same instrument.
Three AC test levels of 0.3Vrms, 0.6Vrms and 1Vrms allow the measurement signal to be selected for the task. A 40,000-count primary display, secondary-parameter readout and Mini-USB connection support component evaluation at the workbench and transfer of readings to a PC.
Key Features
-
Selectable test frequencies: Five fixed AC settings through 100kHz let you compare component readings at a defined test frequency.
-
Dual-parameter display: Read the primary component value with a related secondary parameter on the dual LCD. The primary display provides up to 40,000 counts; basic accuracy is 0.1% under the conditions specified in the operation manual.
-
LCR, impedance and DCR measurements: Check L, C, R and impedance with AC excitation, then use DCR for direct DC resistance measurement. D, Q, phase angle and ESR provide additional component information.
-
Three selectable AC levels: Choose 0.3Vrms, 0.6Vrms or 1Vrms to define the AC test signal for the measurement task.
-
Tolerance sorting: Use 1%, 5%, 10% or 20% tolerance settings to sort components against a stored nominal value. Auto LCR selection assists with mixed component checks.
-
Mini-USB PC communication: A virtual serial interface supports remote control and transfer of measurement results, so readings can be collected as part of a PC-based workflow.
Applications
- Checking resistors, capacitors and inductors during electronics repair and maintenance.
- Evaluating AC component parameters and DC resistance at the workbench.
- Sorting components against a nominal value with the tolerance function.
Why Choose the TH2822E?
Choose the TH2822E when your portable component-checking workflow needs both a 100kHz AC test point and DC resistance measurement. The five frequency settings, selectable AC levels and tolerance mode combine defined measurement conditions with practical component sorting and PC communication.
Basic accuracy depends on the measurement frequency, range, test level and operating conditions. See the operation manual for the applicable accuracy tables.
Source