{"product_id":"rigol-rpl1116-16-channel-logic-probe-ds1000z-plus","title":"RIGOL RPL1116 16-Channel Logic Probe for DS1000Z Plus","description":"\u003cp\u003eThe RIGOL RPL1116 is a 16-channel active logic probe that connects digital signals from a device under test to compatible RIGOL DS1000Z Plus and MSO1000Z oscilloscopes. It adds digital-channel acquisition for mixed-signal debugging, logic timing analysis and correlation between analog and digital circuit behavior.\u003c\/p\u003e\n\n\u003cp\u003eSixteen channels labeled D0–D15 allow engineers to examine data lines, address buses, control signals and other related digital events on the same oscilloscope used for analog waveform measurements.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e16 digital input channels:\u003c\/strong\u003e Captures multiple related logic signals for bus, timing and state analysis.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTwo channel groups:\u003c\/strong\u003e Channels are organized as D0–D7 and D8–D15 for structured multi-channel measurements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndependent group thresholds:\u003c\/strong\u003e Each eight-channel group can use a separate threshold level for systems containing different logic-voltage families.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e±15V threshold range:\u003c\/strong\u003e Supports adjustment for a broad range of digital signal levels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e500mV minimum voltage swing:\u003c\/strong\u003e Detects logic transitions with relatively small signal amplitudes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e10ns minimum detectable pulse:\u003c\/strong\u003e Captures short digital events and narrow control pulses.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh input impedance:\u003c\/strong\u003e The 100kΩ input resistance reduces loading on digital test points.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible connections:\u003c\/strong\u003e Twenty leads and twenty grabbers support signal and reference-ground connections across development boards and assembled circuits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe auto-calibration:\u003c\/strong\u003e Zero calibration is available through the oscilloscope’s logic-analyzer menu.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOscilloscope Compatibility\u003c\/h3\u003e\n\n\u003cp\u003eThe RPL1116 is designed for the digital input interface used by the RIGOL MSO1000Z and compatible DS1000Z Plus families. Supported DS1000Z Plus models include:\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003eRIGOL DS1074Z Plus\u003c\/li\u003e\n  \u003cli\u003eRIGOL DS1104Z Plus\u003c\/li\u003e\n  \u003cli\u003eRIGOL DS1074Z-S Plus\u003c\/li\u003e\n  \u003cli\u003eRIGOL DS1104Z-S Plus\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eAdding the RPL1116 to a compatible DS1000Z Plus or DS1000Z-S Plus oscilloscope enables its 16 digital input channels and mixed-signal measurement workflow. The probe is not intended as a universal logic accessory for RIGOL oscilloscopes without the corresponding digital input interface.\u003c\/p\u003e\n\n\u003ch3\u003eMixed-Signal Debugging\u003c\/h3\u003e\n\n\u003cp\u003eDigital waveforms from the RPL1116 can be displayed alongside the oscilloscope’s analog channels. This enables direct examination of relationships such as a control signal changing before a power rail responds, a clock transition preceding analog noise or a logic event triggering an unexpected circuit condition.\u003c\/p\u003e\n\n\u003cp\u003eChannel labels and adjustable waveform sizes help organize complex acquisitions when multiple digital lines are active.\u003c\/p\u003e\n\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eMicrocontroller and embedded-system debugging\u003c\/li\u003e\n  \u003cli\u003eFPGA and programmable-logic testing\u003c\/li\u003e\n  \u003cli\u003eParallel data- and address-bus analysis\u003c\/li\u003e\n  \u003cli\u003eDigital control-signal verification\u003c\/li\u003e\n  \u003cli\u003eTiming relationship measurements\u003c\/li\u003e\n  \u003cli\u003eMixed analog and digital circuit diagnostics\u003c\/li\u003e\n  \u003cli\u003ePrototype development and validation\u003c\/li\u003e\n  \u003cli\u003eElectronics education and laboratory experiments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eProbe Specifications\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput channels:\u003c\/strong\u003e 16\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChannel groups:\u003c\/strong\u003e D0–D7 and D8–D15\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThreshold range:\u003c\/strong\u003e ±15V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThreshold accuracy:\u003c\/strong\u003e ±(100mV + 3% of threshold setting)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum input voltage:\u003c\/strong\u003e ±40V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum input dynamic range:\u003c\/strong\u003e ±10V plus threshold setting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum voltage swing:\u003c\/strong\u003e 500mV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum detectable pulse width:\u003c\/strong\u003e 10ns\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput impedance:\u003c\/strong\u003e 100kΩ±2%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput capacitance:\u003c\/strong\u003e approximately 8pF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMain cable length:\u003c\/strong\u003e approximately 90cm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput lead length:\u003c\/strong\u003e approximately 25cm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating environment:\u003c\/strong\u003e 0–50°C, 0–80%RH\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConnection Quality\u003c\/h3\u003e\n\n\u003cp\u003eIndividual signal leads can connect directly to test points or be combined with the supplied grabbers. Channel markings and color identification simplify connection tracing when several digital lines are measured simultaneously.\u003c\/p\u003e\n\n\u003cp\u003eFor measurements where crosstalk or ground bounce is a concern, RIGOL recommends pairing each signal lead with a nearby ground lead and twisting the signal and ground conductors together.\u003c\/p\u003e\n\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eRPL1116 active logic probe head\u003c\/li\u003e\n  \u003cli\u003eMain connection cable\u003c\/li\u003e\n  \u003cli\u003e20 input leads\u003c\/li\u003e\n  \u003cli\u003e20 grabber clips\u003c\/li\u003e\n  \u003cli\u003eChinese and English user guide\u003c\/li\u003e\n  \u003cli\u003eRPL1116 packaging box\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Choose the RIGOL RPL1116?\u003c\/h3\u003e\n\n\u003cp\u003eThe RPL1116 converts a compatible DS1000Z Plus oscilloscope into a mixed-signal measurement platform with 16 digital channels. It is a direct upgrade for engineers, students and technicians who need to correlate analog waveforms with logic activity without using a separate logic analyzer.\u003c\/p\u003e","brand":"RIGOL","offers":[{"title":"Default Title","offer_id":54649867338007,"sku":null,"price":283.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1014\/1414\/2231\/files\/RIGOL_RPL1116.webp?v=1786428966","url":"https:\/\/aimitek.eu\/products\/rigol-rpl1116-16-channel-logic-probe-ds1000z-plus","provider":"Aimitek","version":"1.0","type":"link"}