{"product_id":"rigol-rp1025d-rp1050d-rp1100d-differential-probes","title":"RIGOL RP1025D\/RP1050D\/RP1100D High-Voltage Differential Probes","description":"\u003cp\u003eThe RIGOL RP1025D, RP1050D and RP1100D are powered high-voltage differential probes that convert high differential voltages into low-voltage signals suitable for oscilloscope display. They enable waveform measurement between two circuit points while providing high input impedance and common-mode rejection.\u003c\/p\u003e\n\n\u003cp\u003eThe three models cover bandwidths from DC–25MHz to DC–100MHz. Multiple attenuation settings support measurements ranging from lower-voltage control circuits to high-voltage inverter, motor-drive and power-conversion systems.\u003c\/p\u003e\n\n\u003ch3\u003eModel Differences \u0026amp; Selection\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRP1025D – Lower-voltage power electronics:\u003c\/strong\u003e Provides DC–25MHz bandwidth with 20X, 50X and 200X attenuation. Its maximum differential input is 1400Vpp, 500Vrms or 500VDC. Select it for power supplies, mains-related measurements and converters that do not require the higher voltage capacity of the RP1050D or RP1100D.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRP1050D – High voltage with 50MHz bandwidth:\u003c\/strong\u003e Provides DC–50MHz bandwidth, 100X to 1000X attenuation and a maximum differential input of 7000Vpp, 2300Vrms or 2300VDC. It suits high-voltage inverters, industrial drives and power converters where voltage capacity is more important than 100MHz bandwidth.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRP1100D – High voltage with faster edge capture:\u003c\/strong\u003e Retains the 7000Vpp maximum differential input and 100X to 1000X attenuation of the RP1050D while increasing bandwidth to DC–100MHz. Choose it for faster switching devices, gate-drive analysis and high-frequency power-conversion waveforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe RP1050D and RP1100D provide the same principal voltage ranges. The purchasing decision between them is therefore based primarily on bandwidth: 50MHz for general high-voltage power testing or 100MHz for faster switching edges and shorter transient events.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrue differential measurement:\u003c\/strong\u003e Measures voltage between two circuit points without connecting either test lead directly to the oscilloscope ground.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUp to 7000Vpp differential input:\u003c\/strong\u003e Supports high-voltage measurements in industrial power-conversion and drive systems with the RP1050D and RP1100D.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUp to 100MHz bandwidth:\u003c\/strong\u003e The RP1100D captures faster switching transitions and transient behavior.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSelectable attenuation:\u003c\/strong\u003e Multiple ranges allow the probe output to be matched to the signal amplitude and oscilloscope input.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e±2% accuracy:\u003c\/strong\u003e Provides consistent amplitude measurements under the specified operating conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh input impedance:\u003c\/strong\u003e Reduces loading on high-voltage circuits and switching nodes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommon-mode rejection above 50dB:\u003c\/strong\u003e Suppresses voltage common to both inputs at the specified test frequencies.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOverload indicator:\u003c\/strong\u003e Provides a visible warning when the selected attenuation range is exceeded.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard BNC output:\u003c\/strong\u003e Connects to general-purpose oscilloscopes through the supplied 50Ω coaxial cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExternal 9VDC power:\u003c\/strong\u003e The supplied adapter supports continuous laboratory and production use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eSwitching power-supply development\u003c\/li\u003e\n  \u003cli\u003eInverter input and output measurements\u003c\/li\u003e\n  \u003cli\u003eMotor-drive and variable-frequency drive testing\u003c\/li\u003e\n  \u003cli\u003eIGBT, MOSFET and SiC switching waveform analysis\u003c\/li\u003e\n  \u003cli\u003eGate-driver and floating-node measurements\u003c\/li\u003e\n  \u003cli\u003eDC bus and power-converter testing\u003c\/li\u003e\n  \u003cli\u003eIndustrial power equipment maintenance\u003c\/li\u003e\n  \u003cli\u003eElectronic ballast and lighting-system diagnostics\u003c\/li\u003e\n  \u003cli\u003eRenewable-energy and energy-storage power systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAttenuation and Oscilloscope Input\u003c\/h3\u003e\n\n\u003cp\u003eThe marked attenuation ratios apply when the oscilloscope input impedance is set to 1MΩ. If the probe is connected to a 50Ω oscilloscope input, the effective attenuation ratio doubles. For example, a marked 200X setting operates as 400X with a 50Ω input.\u003c\/p\u003e\n\n\u003cp\u003eMatching the oscilloscope probe setting to the effective attenuation ratio allows the displayed vertical scale to represent the actual differential voltage.\u003c\/p\u003e\n\n\u003ch3\u003eMeasurement Performance\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRP1025D:\u003c\/strong\u003e DC–25MHz bandwidth, 14ns rise time and 4MΩ differential input resistance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRP1050D:\u003c\/strong\u003e DC–50MHz bandwidth, 7ns rise time and 16MΩ differential input resistance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRP1100D:\u003c\/strong\u003e DC–100MHz bandwidth, 3.5ns rise time and 16MΩ differential input resistance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±2%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput impedance:\u003c\/strong\u003e 50Ω\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommon-mode rejection:\u003c\/strong\u003e greater than 50dB at 60Hz, 100Hz and 1MHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSafety and Voltage-to-Ground Limits\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRP1025D maximum voltage to ground:\u003c\/strong\u003e 240Vrms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRP1050D maximum voltage to ground:\u003c\/strong\u003e 1200Vrms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRP1100D maximum voltage to ground:\u003c\/strong\u003e 1200Vrms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety classification:\u003c\/strong\u003e CAT III, Pollution Degree 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation:\u003c\/strong\u003e Double insulation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating environment:\u003c\/strong\u003e Indoor use\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe effective voltage limit is determined by the lowest rating of the probe, attenuation setting, test leads, clips and connected instrument. The high-voltage IC clips supplied with the RP1050D and RP1100D are rated up to 6500Vpp.\u003c\/p\u003e\n\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eRP1025D, RP1050D or RP1100D differential probe\u003c\/li\u003e\n  \u003cli\u003eAC power adapter for the destination country\u003c\/li\u003e\n  \u003cli\u003e100cm dual-BNC 50Ω coaxial cable\u003c\/li\u003e\n  \u003cli\u003eRed and black 60cm silicone test leads\u003c\/li\u003e\n  \u003cli\u003eRed and black measurement clips\u003c\/li\u003e\n  \u003cli\u003eChinese and English user guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe RP1050D and RP1100D include dedicated high-voltage silicone leads and high-voltage IC clips. The RP1100D additionally includes red and black CAT III contact probe rods.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Choose the RIGOL RP1000D Series?\u003c\/h3\u003e\n\n\u003cp\u003eThe RP1000D Series provides a practical choice of voltage range and bandwidth for high-voltage differential measurements. The RP1025D covers lower-voltage power applications, the RP1050D extends the range to 7000Vpp, and the RP1100D combines the same voltage capacity with 100MHz bandwidth for faster switching technologies.\u003c\/p\u003e","brand":"RIGOL","offers":[{"title":"RP1025D","offer_id":55093685256471,"sku":null,"price":449.99,"currency_code":"USD","in_stock":true},{"title":"RP1050D","offer_id":55093685289239,"sku":null,"price":599.99,"currency_code":"USD","in_stock":true},{"title":"RP1100D","offer_id":55093685322007,"sku":null,"price":718.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1014\/1414\/2231\/files\/RIGOL_RP1050D.webp?v=1786418704","url":"https:\/\/aimitek.eu\/products\/rigol-rp1025d-rp1050d-rp1100d-differential-probes","provider":"Aimitek","version":"1.0","type":"link"}